中国区总部
毕孚自动化设备贸易(上海)有限公司

市北智汇园4号楼
静安区汶水路 299 弄 9-10 号
上海, 200072, 中国

+86 21 6631 2666
info@beckhoff.com.cn
www.beckhoff.com.cn/zh-cn/

ED2828 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 2 A, push-inNew

Image similar, may contain optional accessories
ED2828 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 2 A, push-in

ED2828 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 2 A, push-in

Image similar, may contain optional accessories
ED2828 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 2 A, push-in

ED2828 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 2 A, push-in

Ch. 1 DO
Ch. 2 DO
Ch. 3 DO
Ch. 4 DO
Ch. 5 DO
Ch. 6 DO
Ch. 7 DO
Ch. 8 DO
Power contact
+24 V DC
Power contact
0 V
Ch. 1 digital output
Ch. 2 digital output
Ch. 3 digital output
Ch. 4 digital output
Ch. 5 digital output
Ch. 6 digital output
Ch. 7 digital output
Ch. 8 digital output
0 V
0 V
0 V
0 V
0 V
0 V
0 V
0 V
ED2828 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 2 A, push-in

ED2828 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 2 A, push-in

ED2828 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 2 A, push-in

ED2828 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 2 A, push-in

The ED2828 digital output terminal connects the binary 24 V DC control signals from the automation device on to the actuators at the process level with electrical isolation. The EtherCAT Terminal contains eight channels whose signal state is indicated by light emitting diodes (status LEDs). The power contacts are looped through. In the EL2828 the outputs are supplied via the 24 V DC power contact.

 

Special features:

  • suitable for controlling different types of loads:
    • resistive loads (e.g., resistors)
    • inductive loads (e.g., relays, contactors, valves)
    • capacitive loads
  • max. output current of 2 A per channel (∑ 10 A)
  • short-circuit proof outputs: protection against overload or short circuit
  • reverse polarity protection in the event of incorrect polarity of the supply voltage

The ED-series EtherCAT Terminals have push-in connection technology which makes wiring easy and tool-free.

Product status:

product announcement | estimated market release 1st quarter 2026

Product information

GeneralED2828
Number of channels | Total8
Internal communication protocolEtherCAT
Digital outputED2828
Standard digital | Positive switching
Number of channels8
Load typeohmic, inductive, capacitive
Connection technology1-wire, 2-wire
Signal range | Nominal24 V DC
Signal range | Technical20.4…28.8 V DC
Output currentmax. 2 A per channel
Output current | ∑max. 10 A
Short-circuit proofyes
Output stagepush
Reverse voltage protectionja
XFCED2828
Distributed clocksno
Timestampno
Oversamplingno
Supply and electrical isolationED2828
Electronics | Supply voltagevia E-bus, via power contacts
Power contacts | Input voltage24 V DC (-15 %/+20 %)
Power contacts | Current carrying capacitymax. 10 A
Power contacts | Output voltagecorresponds to Power contacts | input voltage
Electrical isolation | Channel/channelno
Electrical isolation | Channel/busfunctional, 707 V DC type test
Environmental conditionsED2828
Operating temperature-25…+60°C
Storage temperature-40…+85°C
Relative humidity95%, no condensation
Installation positionvariable
Standards and approvalsED2828
Vibration resistanceconforms to EN 60068-2-6
Shock resistanceconforms to EN 60068-2-27
EMC immunityconforms to EN 61000-6-2
EMC emissionconforms to EN 61000-6-4
MarkingsCE
Housing dataED-12-16pin
Weight60 g
Protection ratingIP20
Materialpolycarbonate
Dimesnions | Width (single)15 mm
Dimensions | Width (lined up)12 mm
Dimensions | Height100 mm
Dimensions | Depth65 mm
Installation | Terminal/back wallDIN rail, 35 mm (EN 60715)
Installation | Terminal/terminaldouble slot and key connection
Plug-in wiring levelno
Connection technologypush-in
Connection cross-section | Solid wire0.08…1.5 mm²
Connection cross-section | Stranded wire0.25…1.5 mm²
Connection cross-section | With ferrule0.14…0.75 mm²
Connection cross-section AWG | Solid wireAWG28…16
Connection cross-section AWG | Stranded wireAWG22…16
Connection cross-section AWG | With ferruleAWG26…19
Stripping length8…9 mm
Power contact | "+" (left)yes
Power contact | "+" (rechts)yes
Power contact | "-" (left)yes
Power contact | "-" (right)yes
Power contact | "⏚" (left)
no
Power contact | "⏚" (right)no
Insertion lock for power contact “⏚” yes

Loading content ...

Loading content ...

Loading content ...

© Beckhoff Automation 2025 - Terms of Use