ED2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, push-inNew

Image similar, may contain optional accessories
ED2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, push-in

ED2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, push-in

Image similar, may contain optional accessories
ED2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, push-in

ED2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, push-in

Ch. 1 DO
Ch. 3 DO
Ch. 5 DO
Ch. 7 DO
Ch. 2 DO
Ch. 4 DO
Ch. 6 DO
Ch. 8 DO
Power contact
+24 V DC
Power contact
0 V
Ch. 1 digital output
Ch. 3 digital output
Ch. 5 digital output
Ch. 7 digital output
Ch. 2 digital output
Ch. 4 digital output
Ch. 6 digital output
Ch. 8 digital output
ED2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, push-in

ED2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, push-in

ED2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, push-in

ED2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, push-in

The ED2008 digital output terminal connects the binary 24 V DC control signals from the automation device on to the actuators at the process level with electrical isolation. The EtherCAT Terminal has eight channels that indicate their signal state via light emitting diodes (status LEDs). The power contacts are looped through internally. In the ED2008 the outputs are supplied via the 24 V DC power contact.

 

Special features:

  • suitable for controlling different types of loads:
    • resistive loads (e.g., resistors)
    • inductive loads (e.g., relays, contactors, valves)
    • capacitive loads
  • max. output current of 0.5 A per channel
  • positive switching
  • short-circuit proof outputs: protection against overload or short circuit
  • reverse polarity protection in the event of incorrect polarity of the supply voltage

The ED-series EtherCAT Terminals have push-in connection technology which makes wiring easy and tool-free.

Product status:

product announcement | estimated market release 1st quarter 2026

Product information

GeneralED2008
Number of channels | Total8
Internal communication protocolEtherCAT
Digital outputED2008
Standard digital | Positive switching
Number of channels8
Load typeohmic, inductive, capacitive
Connection technology1-wire
Signal range | Nominal24 V DC
Signal range | Technical20.4…28.8 V DC
Output currentmax. 0.5 A per channel
Short-circuit proofyes
Short circuit current limittyp. < 2 A
Output stagepush
Switching times | TONtyp. 140 µs
Switching times | TOFFtyp. 300 µs
Reverse voltage protectionja
Breaking energy | Inductive< 150 mJ per channel
XFCED2008
Distributed clocksno
Timestampno
Oversamplingno
Supply and electrical isolationED2008
Electronics | Supply voltagevia E-bus, via power contacts
E-bus | Current consumptiontyp. 80 mA
Power contacts | Input voltage24 V DC (-15 %/+20 %)
Power contacts | Current carrying capacitymax. 10 A
Power contacts | Current consumptiontyp. 15 mA + load
Power contacts | Output voltagecorresponds to Power contacts | input voltage
Electrical isolation | Channel/channelno
Electrical isolation | Channel/busfunctional, 707 V DC type test
Environmental conditionsED2008
Operating temperature-25…+60°C
Storage temperature-40…+85°C
Relative humidity95%, no condensation
Installation positionvariable
Standards and approvalsED2008
Vibration resistanceconforms to EN 60068-2-6
Shock resistanceconforms to EN 60068-2-27
EMC immunityconforms to EN 61000-6-2
EMC emissionconforms to EN 61000-6-4
MarkingsCE
ApprovalscULus (in preparation)
Housing dataED-12-8pinEF-12-8pin
Weight55 g60 g
Protection ratingIP20
Materialpolycarbonate
Dimesnions | Width (single)15 mm
Dimensions | Width (lined up)12 mm
Dimensions | Height100 mm
Dimensions | Depth65 mm
Installation | Terminal/back wallDIN rail, 35 mm (EN 60715)
Installation | Terminal/terminaldouble slot and key connection
Plug-in wiring levelnoyes
Connection technologypush-in
Connection cross-section | Solid wire0.08…2.5 mm²0.08…1.5 mm²
Connection cross-section | Stranded wire0.08…2.5 mm²0.08…1.5 mm²
Connection cross-section | With ferrule0.14…1,5 mm²
Connection cross-section AWG | Solid wireAWG28…14AWG28…16
Connection cross-section AWG | Stranded wireAWG28…14AWG28…16
Connection cross-section AWG | With ferruleAWG26…16
Stripping length8…9 mm9…10 mm
Power contact | "+" (left)yes
Power contact | "+" (rechts)yes
Power contact | "-" (left)yes
Power contact | "-" (right)yes
Power contact | "⏚" (left)
no
Power contact | "⏚" (right)no
Insertion lock for power contact “⏚” yes
Ordering information
ED2008EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, push-in
EF2008EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, push-in, pluggable wiring level